PT-40U Battery Charger
Newmar’s Phase Three Series Battery Chargers employ “Smart” battery charging technology for 12-volt systems aboard marine applications including workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.
A selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. This model is housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.
Features:
- 12-volt model
 - “Smart” circuitry provides three-stage charging – bulk, absorption, and float
 - Gel-Cell/Flooded Lead-acid/AGM battery type switch selects optimum charge/float voltages
 - Multiple isolated output banks; ammeter indicates total output current. (Except PT-7)
 - The optional sensor adjusts the output voltage based on battery temperature. (Except PT-7)
 - Current limitations prevent damage from overloading
 - Clean well-regulated output can be used as a power supply; can power loads directly without a battery in line
 - Built to last – rugged stainless steel case with a durable white powder coat finish, an optional drip shield, and marinized internal circuitry
 - Protection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield
 - ABS-type approval for battery charging and power supplies
 
Specifications:
- Input VAC (50-60 Hz.): 90-264
 - Input Amps @ Full Load: @ 115 VAC: 6.8, @ 230 VAC: 3.4
 - Power Factor: .98 @ 115V and .95 @ 230V
 - Max Output Amps: 40
 - Output Banks: 3
 - Battery Capacity (Amp-Hours): 80-400
 - Operating Temp. Rating Reference: T-5
 - Case Size Reference: A-3
 - Case Size (H x W x D): 13.85B x 9.5 x 4.8B inches (35.2B x 24.1 x 12.2B centimeters) *Note with Dripshield installed B add .75” (1.9 cm) to height and 1.35” (3.4 cm) to depth
 - Weight Lbs./Kg: 11/6
 - Optional Temp. Sensor Model: TCS-12/24
 - Remote Panel Model: EVM-12-2
 - Equalize Option: No
 - Output Indicator Reference: M-3
 - Compliance Reference: CG
 
Temperature Rating References:
- Temperature: -20 degrees C to +70 degrees C
 - Derate Linearly From 100% @ 50 degrees C to 50% @ 70 degrees C
 
Nominal Output Voltages at Gel/Flooded Switch Settings (without Temperature Compensation):
- Gel-Cell: 14.0 VDC Charge @ 50% load and 13.6 VDC Float @ .5 amp load
 - Flooded/AGM: 14.2 VDC Charge @ 50% load and 13.4 VDC Float @ .5 amp load
 
Compliance References:
- CG: USCG CFR 183.410 (Ignition protected)
 - CE: Carries the CE mark
 - ABS: PT Series meets SVR 2009 4-8-3/5.9, Under 90 meters Rules 2006 4-6-4/7.19, and HSNC 2007 4-8-3/5.13.
 
Options:
- Remote Panel, model EVM-12-2, for us with model PT-40 only (Enables monitoring of when the battery charger is “on” and the batteries’ state of readiness, at a glance of two (2) battery banks only)
 - Temperature Compensation Sensor, Model TCS 12/24, for use with all models except PT 7 (-5 mV per cell degrees C, 25′ cable (40’cable optional)
 
Specifications:
- Charger Input - Voltage: 115/230v
 - Charger Output - Amps: 40a
 - Charger Output Voltage: 12v
 - Charging Banks: 3
 - Inverter Input Voltage: 115/230v
 - Inverter Output Voltage: 12v
 - Outlet Qty: Hardwire
 - Portable: No
 - Box Dimensions: 11"H x 15"W x 20"L WT: 14.7 lbs
 
Quick Guide (pdf)
Owner's Manual (pdf)